1. Define the Purpose of the Laboratory

Start by identifying the laboratory's main activities.

These may include:

  • research and development,
  • quality control,
  • chemical analysis,
  • microbiology,
  • food testing,
  • water and environmental analysis,
  • pharmaceutical analysis,
  • education,
  • production control.

The intended purpose influences almost every subsequent decision.

2. Create a List of Analyses and Methods

A good laboratory should be designed around its analytical methods.

The recommended sequence is:

Analysis → Method → Required Performance → Instrument → Consumables

For each method, determine the required measurement range, accuracy, sample volume, preparation procedure, equipment, chemicals, glassware and consumables.

This helps prevent unnecessary equipment purchases.

3. Plan the Laboratory Layout

An efficient laboratory requires a logical workflow.

A typical process may follow:

Sample Reception → Sample Preparation → Analysis → Instrument Measurement → Data Evaluation → Sample/Waste Management

Where required, clean and contaminated areas should be separated.

4. Select Appropriate Laboratory Benches

Laboratory worktops may need resistance to:

  • chemicals,
  • water,
  • heat,
  • mechanical wear.

The required material depends on the activities performed in the laboratory.

Instrument weight and sensitivity to vibration should also be considered.

5. Plan the Electrical Infrastructure

Before installation, evaluate:

  • operating voltage,
  • power consumption,
  • socket requirements,
  • grounding,
  • UPS requirements,
  • protection against voltage fluctuations.

Sensitive analytical instruments may require particularly stable electrical conditions.

6. Plan Water, Gas, Vacuum and Compressed Air

Depending on the laboratory, utilities may include:

  • tap water,
  • purified water,
  • deionized water,
  • ultrapure water,
  • laboratory gases,
  • compressed air,
  • vacuum.

These requirements should be identified before laboratory construction is completed.

7. Determine Ventilation and Fume Hood Requirements

Operations involving volatile, corrosive or hazardous chemicals may require suitable ventilation and fume hoods.

Fume hood selection should consider the process, chemicals, airflow performance, exhaust system and overall laboratory ventilation.

8. Select Instruments According to the Application

Common laboratory instruments may include:

  • analytical and precision balances,
  • pH meters,
  • conductivity meters,
  • spectrophotometers,
  • refractometers,
  • microscopes,
  • centrifuges,
  • magnetic stirrers,
  • hot plates,
  • ovens,
  • incubators,
  • water baths,
  • ultrasonic cleaners,
  • homogenizers.

Equipment should be selected according to analytical requirements rather than price alone.

9. Evaluate Instrument Specifications

Important criteria may include:

CriterionImportance
Measurement rangeMust cover the required samples
ResolutionAbility to display small differences
AccuracyCloseness to the reference value
RepeatabilityConsistency of repeated measurements
CapacitySuitable for sample workload
CalibrationMeasurement reliability
ServiceLong-term support
Spare partsEquipment sustainability
ConsumablesOperating costs
Data connectivityDigital workflow integration

The instrument with the highest specification is not necessarily the best choice. The correct instrument is the one that reliably meets the method requirements.

10. Plan Laboratory Glassware

Essential laboratory glassware may include:

  • beakers,
  • Erlenmeyer flasks,
  • volumetric flasks,
  • graduated cylinders,
  • pipettes,
  • burettes,
  • reagent bottles,
  • test tubes,
  • round-bottom flasks,
  • separatory funnels,
  • condensers,
  • desiccators.

The glass type and applicable product standard should be selected according to the intended application.

11. Why Is Borosilicate 3.3 Commonly Used?

Borosilicate 3.3 is widely used in laboratory glassware because of its:

  • low thermal expansion,
  • good thermal shock resistance,
  • high hydrolytic resistance,
  • good resistance to many chemicals,
  • high transparency.

However, chemical and thermal resistance are not unlimited. Actual working conditions must always be considered.

12. Check Accuracy Classes for Volumetric Glassware

For quantitative work, volumetric tolerances are important.

Burettes, pipettes, volumetric flasks and graduated cylinders may be available in different accuracy classes, such as Class A, AS or B.

The class required by the analytical method should be selected.

13. Check the Polymer Used in Plastic Labware

Laboratory plastics can be manufactured from different polymers, including:

  • PP,
  • PE,
  • HDPE,
  • LDPE,
  • PTFE,
  • PS,
  • PVC,
  • PVDF.

Their chemical resistance, temperature limits and mechanical properties differ significantly.

Always verify material compatibility with the intended application.

14. Select the Correct Chemical Grade

The same chemical may be available in several grades, including:

  • ACS Reagent,
  • ISO Reagent,
  • Ph. Eur. Reagent,
  • USP,
  • Analytical Reagent,
  • HPLC,
  • GC,
  • Synthesis,
  • Technical.

The highest purity is not automatically required for every application.

Chemical grade should be selected according to the analytical method.

15. Design Chemical Storage Correctly

Chemicals should not be stored solely in alphabetical order.

Depending on compatibility and hazards, separate storage may be necessary for:

  • flammables,
  • acids,
  • bases,
  • oxidizers,
  • toxic substances.

The Safety Data Sheet (SDS) should be consulted when developing storage procedures.

16. Include Laboratory Safety Equipment

Depending on the risk assessment, laboratory safety equipment may include:

  • safety glasses,
  • suitable gloves,
  • laboratory coats,
  • face shields,
  • emergency eyewash stations,
  • safety showers,
  • fire extinguishers,
  • chemical spill kits,
  • first-aid equipment.

Personal protective equipment should complement—not replace—engineering controls and safe operating procedures.

17. Develop an Emergency Plan

Before operation begins, procedures should be established for situations such as:

  • chemical spills,
  • fires,
  • gas leaks,
  • electrical failures,
  • broken glass,
  • chemical exposure.

Emergency exits and safety equipment must remain easily accessible.

18. Establish Calibration and Verification Programs

Purchasing an instrument does not complete the measurement system.

Depending on the quality system and analytical method, laboratories may require planned:

  • calibration,
  • verification,
  • performance checks,
  • preventive maintenance.

Balances, pipettes, thermometers, pH meters and other measuring devices should be included in appropriate control programs.

19. Consider Maintenance and Technical Service Before Purchasing

The true cost of laboratory equipment includes more than its purchase price:

Purchase + Consumables + Maintenance + Calibration + Spare Parts + Service + Equipment Lifetime

Local technical support and spare-part availability can therefore be critical purchasing criteria.

20. Consider Current and Future Capacity

A laboratory processing 20 samples per day today may need to process 100 in the future.

Equipment capacity should therefore account for reasonable future growth without unnecessarily oversizing the system.

21. Consider Ergonomics

Laboratory staff may use the same workstations for many hours.

Consider:

  • bench height,
  • seating,
  • display position,
  • pipetting areas,
  • computer placement,
  • access to frequently used materials.

Good ergonomics contributes to safer and more efficient routine work.

22. Plan Waste Management from the Beginning

Depending on laboratory activities, waste streams may include:

  • chemical waste,
  • solvent waste,
  • broken glass,
  • biological waste,
  • sharps,
  • contaminated packaging.

Waste segregation, labeling, temporary storage and disposal should comply with applicable regulations and institutional procedures.

23. Establish a Documentation System

A professional laboratory requires traceability.

Depending on the operation, documentation may include:

  • SOPs,
  • equipment instructions,
  • maintenance records,
  • calibration records,
  • chemical inventories,
  • SDS files,
  • sample records,
  • analytical results,
  • training records.

24. Identify Applicable Standards and Regulations

Requirements depend on the laboratory's activities and jurisdiction.

Relevant frameworks may include:

  • ISO/IEC 17025,
  • GLP,
  • GMP,
  • pharmacopoeias,
  • industry-specific ISO standards,
  • national regulations.

These requirements should ideally be considered during the design phase rather than after the laboratory has already been built.

25. Prepare a Complete Laboratory Budget

The budget should include more than instruments.

Budget AreaExamples
InfrastructureElectricity, water, gas, ventilation
FurnitureBenches, cabinets, chemical storage
InstrumentsAnalytical and general equipment
GlasswareGeneral and volumetric glassware
ConsumablesTips, filters, tubes, etc.
ChemicalsReagents, standards, solvents
SafetyPPE, eyewash, spill kits
CalibrationInitial and periodic calibration
ServiceInstallation and maintenance
SoftwareInstrument/data management
TrainingEquipment and safety training

A reasonable allowance for unexpected requirements should also be considered.

Common Laboratory Setup Mistakes

Common mistakes include purchasing instruments before defining analytical methods, failing to plan utilities around equipment locations, ignoring technical-service availability, inadequate chemical segregation, overlooking ventilation requirements, neglecting calibration costs and treating safety equipment as an afterthought.

A–Z Laboratory Setup Checklist

A practical planning sequence is:

Purpose → Analyses → Methods → Layout → Workflow → Utilities → Ventilation → Furniture → Instruments → Glassware → Consumables → Chemicals → Safety → Calibration → Technical Service → Documentation → Waste Management → Training

Conclusion

Successful laboratory setup is not about purchasing as much equipment as possible. It is about creating the right infrastructure and selecting the right equipment for the intended analyses.

A properly designed laboratory should be:

safe, efficient, analytically reliable, sustainable and adaptable to future requirements.

Laboratory instruments, chemicals, glassware, consumables, infrastructure and safety systems should therefore not be considered separately. They are all components of the same laboratory ecosystem.

Careful planning at the beginning can reduce unnecessary investment, improve workflow and support reliable laboratory performance for years to come.