N2 GENERATOR FOR LC/MS
Leman-Instruments designed the NITRO18LCMS-60 product line of Nitrogen Generator to meet the gas flow, purity and pressure requirements of the latest generation of almost LC/MS instruments.Models with outflows of 60 L/min N2 are available.
APPLICATIONS
Nebulizing, sheath and drying gas for LC / MS
Solvent Evaporator
Life science researches
Functioning Principle : Partially dried compressed Air is provided by the internal, scroll low noise and oil-free compressor module. (Models without compressor available). Based on the field proven single stage Pressure Swing Adsorbtion (PSA) technology, Nitrogen is then extracted from AIR by a set of filters filled up with CMS. After the extracting process, N2 is stored in a tank and its pressure is regulated electronically to the set value, between 4 and 7.5 bar.(60 to 110 psig). At the instrument’s outlet, N2 is filtered of remaining particulates down to 0.1μm. The NITRO18LCMS line is equipped with a Power Economy function which switches off the compressor and PSA modules when consumption of Nitrogen is reduced or stopped. As option, outflow’s O2 content monitoring and alarm.The NITRO18LCMS line is equipped with a Power Economy function which switches off the compressor and PSA modules when consumption of Nitrogen is reduced or stopped. As option, outflow’s O2 content monitoring and alarm.
BENEFITS
Reduces in operation costs. Return on investment within 18 months. Integrated Power Economy function.
N2 available 24/7 at constant purity. No contamination.
Independent source of High Purity N2.
Integrated oil-free scroll compressor with Air treatment. Can be easily moved around the laboratory.
Low functioning noise
Remote control from PC, I-phone and I-pad.(options)
Very safe operation, internal leak-test, automatic shut-down, protection against over-temperature.
No handling, No storage, No cylinder rental fee.
Internal maintenance free. Long life compressor.
Model |
NITRO18LCMS-60 |
N2 capacity |
NITRO18LCMS-60=60 L/min |
Output N2 purity |
> 99% N2 |
O2 monitoring |
O2 content in N2 outflow with alarm (option) |
Output Pressure |
From 4 to 7.5 bar, adjustable by software. (60 to 110psig) |
Compressed AIR |
Supplied by internal Oil free compressor. Automatic drying. Power Economy |
Manual control |
Through a 4.3” TFT-LCD color display with touchpad, located on the front panel. |
Remote control, |
USB. RS485 (Mod-Bus) or Display.. |
Outlet fitting |
1/4" compression or BSP ¼” female |
Power supply |
100 to 120 VAC 50-60 Hz or 220 to 240VAC, 50 to 60 Hz |
Power Consumption |
NITRO18LCMS-60: max. 2300W, |
Dimensions |
NITRO18LCMS-60:W=55cm, H=120cm, D=80cm |
Net weight |
NITRO18LCMS-60: 240Kg, |
Certification |
CE |
Model |
No |
NITRO18LCMS-60-230 |
75-5217 |
NITRO18LCMS-60 without compressor |
75-5257 |
Options |
No |
O2 monitoring +Alarm |
75-5285 |
Related Products
LAB Equipment
- Balance
- Bath
- Centrifuge
- Incubator
- Muffle Furnace
- Oven
- Hand Held Refractometer
- Shaker
- Spectrophotometer
- Viscometer
- Water distiller
- pH & Conductivity Meter
- Hotplate Stirrers
- Mixer & Rotator
- Homogeniser
- Recirculating Cooler
- Ultrasonic Processor
- Gas Meter and Detectors
- Digital Refractometer
- Benchtop Refractometer
- Polarimeter
- Hydrogen Generators
- Nitrogen Generators
- OXYGEN GENERATOR
- DRY AIR GENERATOR
- HYDROGEN & ZERO AIR GENERATORS
- LCMS GENERATORS