BeyanLab

You are here

UV/visible Double beam spectrophotometer

Product code: 
6850
Features: 

UV/visible Double beam spectrophotometer  (JENWAY)

The new 6850 is a UV/visible double beam spectrophotometer with a variable spectral bandwidth. This spectrophotometer has an integrated user interface for local control and ease of navigation. The 6850 spectrophotometer is ideal for quality control, general research, pharmaceutical, biochemical and clinical laboratory applications.

Features:

  •  Double beam spectrophotometer with highly stable optics
  •  Variable spectral bandwidth 0.5, 1, 2, 4, 5nm
  •  Integrated user interface
  •  USB port for data storage
  •  Conforms to European Pharmacopeia requirements
  •  Jenway Prism PC software included as standard
  •  Extensive range of accessories available
  •  1 year warranty
Technical Specification: 
Parameter 6850
Wavelength range 190 to 1100nm
Wavelength resolution 0.1nm
Wavelength accuracy ± 0.3nm (at 0.5 and 1nm bandwidth) ± 0.5nm (at 2, 4 and 5nm bandwidth)
Wavelength reproducibility ± 0.2nm
Spectral bandwidth Variable 0.5, 1, 2, 4, 5nm
Photometric range - 0.3 to 3.0A 0 to 200%T
Photometric accuracy ± 0.002A (0- 0.5A) ± 0.3% T (0- 100%T)
Photometric reproducibility ± 0.001 Abs (0 to 0.5 Abs) ± 0.002 Abs (0.5 to 1.0 Abs) 0.15%T (0- 100%T)
Resolution 0.1%T, 0.001A
Stray light < 0.05%T at 220 and 360nm
Noise 0.0005A
Stability ± 0.001A/h at 500nm after 15 min warm up
Multi-wavelength Up to 10 wavelengths, up to 20 wavelengths with PC software
Calculations Ratio, difference, formulae with factors
Spectrum range Any range between 190 and 1100nm
Scan speed 100 to 2000nm/min
Scan interval 0.1, 0.2, 0.5, 1, 2 or 5nm
Analysis Auto peaks and valleys, zoom . Addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, overlay with PC software
Kinetics Up to 12 hours with time intervals of 0.1, 0.2, 0.5, 1, 2, 5, 10 or 30 seconds
Analysis Slope and formula of line of best fit between any two points
Quantitation points Up to 3 wavelengths
Quantitation Calibration Blank with up to 10 standards or factor
Concentration range 0- 99999
Calibration Blank with standards or factor
DNA/ RNA and Protein DNA/RNA Ratio, concentration, A320 correction
Light source Tungsten halogen and Deuterium lamps
Lamp changeover 325 to 370nm selec table
Outputs USB and parallel
Operating system: Windows 2000, XP, Vista, Windows 7
Electrical supply 120VA, 220/ 110V, 50/ 60Hz
Size (w x d x h) 600 x 450 x 200mm
Weight 22kg